Susceptibility Tensor Imaging of the Kidney and its Microstructural Underpinnings

 

Luke Xie, Russell Dibb, Gary P. Cofer, Peter J. Nicholls, Wei Li, G. Allan Johnson, Chunlei Li

Magnetic Resonance in Medicine 73:1270-1281, 2015. PMCID: PMC4183741

 

 

Purpose: The purpose of this study was to determine whether susceptibility tensor imaging (STI) could overcome limitations of current techniques to detect tubules throughout the kidney.


Methods: Normal mouse kidneys (n=4) were imaged at 9.4T using a 3D gradient multiecho sequence (55-micron isotropic resolution). Phase images from 12 orientations were obtained to compute the susceptibility tensor. Diffusion tensor imaging (DTI) with 12 encoding directions was compared with STI. Tractography was performed to visualize and track the course of tubules with DTI and STI. Confocal microscopy was used to identify which tubular segments of the nephron were detected by DTI and STI.


Results: Diffusion anisotropy was limited to the inner medulla of the kidney. DTI did not find a significant number of coherent tubular tracks in the outer medulla or cortex. With STI, we found strong susceptibility anisotropy and many tracks in the inner and outer medulla, and in limited areas of the cortex.
Conclusion: STI was able to track tubules throughout the kidney, while DTI was limited to the inner medulla. STI provides a novel contrast mechanism related to local tubule microstructure and may offer a powerful method to study the nephron.

 

Supplementary Data:

CIVM makes many types of data acquired for published and yet unpublished studies available through our CIVM VoxPort application. Use of VoxPort is free. Registration is required. Register for VoxPort access now. A new browser window or tab will open.

We ask that you provide contact information, and agree to give credit to the Duke Center for In Vivo Microscopy for any written or oral presentation using data from this site. Please use the following acknowledgement: Imaging data provided by the Duke Center for In Vivo Microscopy NIH/NIBIB (P41 EB015897).

Instructions: Click on a link below. A new browser window or tab will open where you will be prompted to login to CIVMVoxPort. If you do not have login credentials, follow the instructions to register for access. After you login, come back to this page and re-click on a link below to go directly to the desired page.

 

View Conventional MR imaging in CIVMVoxPort

 

Acknowledgements:

The authors wish to thank the following individuals at Duke University: Steven Earp for custom machining assistance at the Pratt Machine Shop; Dr. Laurence W. Hedlund for animal use protocols and photography of the coil; Dr. John C. Nouls for initial design of specimen cartridge; Dr. Martin C. Fischer for optical calibration and microscopy; and Sally Zimney for editorial assistance. We are also grateful to Dr. Mark A. Knepper at NHLBI of NIH for renal physiology insight. This work was supported in part by the NIH/NCRR/NIBIB national Biomedical Technology Resource Center (P41 EB015897 to G.A.J.), NCI (U24 CA092656 to G.A.J.), and NIMH (R01MH096979 to C.L.).